There are two types of fats present in the foods we eat, i.e. visible and invisible fats. From the word itself, the former refers to fats that can be seen such as those in butter, the cooking oil, and extracted oil from cooking meat. Invisible fats, on the other hand, cannot be seen by the naked eye. It hides in foods like eggs, pastries, confectionery, and snacks.
Photo: Obtained fats from potato chips, sunflower seeds, and chocolate chips. (photo credit: E. Fuentes)
Laboratory Procedure for Extraction of Invisible Lipids from Potato Chips, Chocolate Chips, and Sunflower Seeds:
( obtained from the laboratory report of Chemical Engineering students: R. Barcenas, J. Cas, S.G. Perez, and E. Fuentes).
Materials and Methods
Materials:
Materials
|
Specification
|
Quantity
|
Chocolate
chips
|
Semi-sweet
Chocolate Droplets (brand)
|
7
grams
|
Potato
chips
|
Jack
n’ Jill (brand)
|
7
grams
|
Sunflower
seeds
|
No
brand
|
7
grams
|
Analytical
balance
|
1
|
|
Microwave
|
1
|
|
Paper
towels
|
1 ply
|
|
Acetone
|
60 mL
|
|
Petri
dishes
|
100
mm
|
3
|
beaker
|
50 mL
|
3
|
Stirring
rod
|
glass
|
1
|
Graduated
cylinder
|
glass
|
1
|
hammer
|
1
|
|
Aluminium
foil
|
Procedures:
·
The samples, i.e.,
potato chips, chocolate chips, and sunflower seeds were purchased in the supermarket.
For the visual evidence of invisible fats from foods, heat was used. The three
samples were heated in a microwave. For the quantitative measurement of fats,
acetone was used. The experiment was done for one trial.
A.
Cleaning
of the Work Area
Materials such as analytical
balance, paper towels, acetone, foil, hammer, chocolate chips, sunflower seeds,
and potato chips were prepared and organized on the work stat. Petri dishes,
graduated cylinder, beakers and stirring rod were washed with dishwashing soap
and were dried using paper towels.
B.
Preparation
of Materials
The workstation was
cleaned using liquid Lysol and a clean rug. Next, it wasdisinfected with
Casino Ethyl Alcohol. The cleaning process was done once.
C.
Weighing
of Samples
The analytical
balance was switched on and a sheet of paper towel was placed on it. The
balance was tared. Two grams of the potato chips were weighed. The paper towel
with potato chips was removed from the balance and was set aside. A new set of
paper towel was placed on the analytical balance and tared again. Five grams of the same potato
chips were weighed. It was also set aside. The same process was followed for
chocolate chips and sunflower seeds. Two grams and five grams were weighed
separately for each sample.
D.
Crushing
of Samples into Smaller Pieces
The group cut a piece
of foil from its roll (approximately 10”x4” inches). The piece of foil was
folded into two and the weighed five grams of potato chips were placed in
between. The chips were crushed using hands and were further hammered lightly
with the handle of the scissors. The same went for chocolate chips and
sunflower seeds weighing five grams. However, a metal hammer was used for the
latter instead.
E.
Transferring
of Crushed Samples to Beakers
Using white masking
tape and a pen, the beakers were labelled as follows: potato chips, chocolate
chips, and sunflower seeds. A beaker was weighed on the balance. The datum was
recorded. The crushed potato chips sample in the foil was carefully transferred
to the beaker labelled “potato chips”. The crushed chocolate chips and
sunflower seeds were also transferred to their respective beakers. Each beaker
with sample was weighed and the data were recorded. The mass of the empty
beaker was subtracted from the mass of each beaker with crushed sample. The new
mass of each sample was obtained.
F.
Treating
each Sample with Acetone
10 mL of acetone was
measured using the 10 mL graduated cylinder. It was immediately but carefully
poured to the beaker with potato chips. The said beaker was brought to the fume
hood. It was stirred using a glass rod for one minute. The acetone was poured
into a petri dish leaving the potato chips in the beaker. Another 10 mL acetone
was measured using the graduated cylinder and was immediately poured into the
beaker. It was once again stirred using the rod. After one minute, the acetone
was poured into the same petri dish. This was done to extract maximum fats that
could be extracted. The same process was done for the chocolate chips and
sunflower seeds. Separate petri dishes served as the container for each sample.
Also, the stirring rod was washed first before using it for stirring the other
samples.
G.
Evaporating
the Acetone
The petri dishes with
acetone and the beakers with samples were organized in the fume hood and were
left there for approximately 22 hours (overnight).
H.
Heating
the Sample in Microwave
The weighed two grams
of sunflower seeds and potato chips were microwaved for 25 seconds. For each
sample, the paper towel was folded enclosing the seeds/potato chips right after
it was removed from the microwave. It was set aside for five minutes. The same
process went for the chocolate chips, however, it was microwaved for 40 seconds
instead. Then, the paper towel was opened up revealing wet-like spots.
Observations were made in terms of color, texture, odor and viscousity. The
information was recorded.
I.
Cleaning
of the Work Station
Pieces of waste on
the work station were removed and disposed. Other materials were packed to
clear the area. It was cleaned using Lysol, rug, and ethyl alcohol.
J.
Results
on Dried Samples
The group visited the
laboratory the next day to check on the beakers with samples and petri dishes.
Then, it was weighed and recorded. Observations were also made.
K.
Cleaning
of Laboratory Equipment
The fluid in petri
dishes were transferred to a plastic bottle for wastes. The contents of the
beaker were also disposed. The laboratory materials used were washed with
dishwashing soap and dried using paper towels. The materials were returned to the chemical technician.
thank you for this. made as a reference for my paper.
ReplyDelete